How to Factory Reset Advidia Cameras That Have a Physical Reset Button

$
0
0

Description:

This article shows you how to hard reset or factory reset Advidia cameras that have a physical button.
 
 
Solution:
 

Advidia A-Series with physical reset buttons:   A-15 / A-35 / A-44 / A-44-IR / A-44-IR V2 / A-46 / A-47 / A-54 / A-54-OD / A-54 V2 / A-55 / A-64 / A-65

Advidia B-Series with physical reset buttons:   B-31 / B-33

Advidia VP-Series with physical reset buttons: VP-4 / VP-8 / VP-16

    • Steps:

1.  With the unit powered on, press and hold the reset button on back of unit (or under the dome) for 30 seconds.

2.  Without releasing the reset button, unplug the power cable and hold reset for another 30 seconds.

          • If it is a PoE camera, disconnect the network cable.

3.  Plug the power cable back in STILL holding the reset button a final 30 seconds.

          • If it is a PoE camera, plug in the network cable.
 

Advidia B-Series with physical reset buttons:   B-210 / B-5360

    • Steps:

1.  With the unit powered on, press and hold the reset button on back of unit (or under the dome) for 30 seconds or until the blue LED (underneath the camera module) lights up.

 

Advidia P-Series with physical reset buttons: P-24 / P-25 / P-3360-OD

    • Steps:

1.  With the unit powered off, press and hold the initial set button.

2.  Without releasing the initial set button, power on the camera and hold for 5 seconds.

3.  Release the initial set button and wait 2 minutes for camera to boot and initialize.

 

Advidia P-Series with physical reset buttons: P-240

    • Steps:

1.  With the unit powered off, move the initial set button to the ON position.

2.  Power on the camera. The live indicator will light orange → light off → blink orange → light orange. The initialization will be complete when the live indicator lights orange.

3.  Power off the camera and move the initial set button to the OFF position.

4.  Return the water-resistant cap and the main sunshield rear cover to the original state.

5.  Power the camera back on using the power supply.

 

This will revert all settings including the network back to defaults.  For the camera's default IP address, please visit Advidia's support site: Advidia Camera & Encoder Support

 

NOTE:  The following cameras do NOT have physical reset buttons: VP-1 / VP-16-L / VP-8-V2 / VP-16-V2 / A-14 / A-34 / A-34W / A-45 / A-200 / A-200-P